CONSTRUCTION

Concrete slab-on-grade with concrete footers

FOUNDATION

STRUCTURAL SYSTEM Steel frame structure

EXTERIOR WALLS

Insulated precast with stucco exterior

Weather Stopper Integrated Roofing System by GAF Materials Corporation Glass windows in aluminum frames; primary entries to the building are by glass panel access doors Slab-on-grade on the first floor and concrete over steel deck on the second floor; Floor coverings include medical grade wood-look vinyl tile on the first floor and commercial grade carpet tiles on second floor; ceramic tile in the bathrooms Painted gypsum board over metal studs with carpet and vinyl cove base; metal door frames and solid wood doors; first floor has an x-ray room with lead- lined walls

ROOF

FENESTRATION

FLOORS

INTERIOR PARTITIONS

Primarily suspended acoustical tile ceilings Primarily good quality recessed fluorescent fixtures with some incandescent fixtures

CEILINGS

LIGHTING

Six restrooms on each floor with multiple fixtures; numerous examination rooms with sinks; janitor closet and break rooms with sinks; the plumbing is good for medical office use Adequate electrical service and outlets for a medical office use

PLUMBING

ELECTRICAL

HVAC

Zoned central heat and air

Smoke detection system and fully sprinklered for fire protection

LIFE SAFETY

One elevator with two landings and three exterior stairways; the building has built-in cabinets and/or workstations in the examination rooms, nurse stations, reception areas, etc.

OTHER