Property Highlights

Site Plan Doors Main entrance doors to both buildings are solid cherry wood doors Interior doors throughout the building are cherry wood with insulated glass tops and side panels with a stained glass coding on each floor All stairwell and service center doors throughout the building are aluminum and fire rated as required by codes Elevators Two elevators are located in the main building with the smaller elevator accessing the 5th floor. There is no elevator in the C Building HVAC Air cooled chiller, air handler units on each floor, variable freq drive, 2 boilers, 4 Liebert units (1 for comm room), fan coil units, pumps (4), 4 FM 200 units. There are strategically placed VAV boxes throughout the building for managing controlled temps. Electrical Electrical services provided by Nashville Electric Service with electrical rooms on each floor

Plumbing The building consists of 14 bathrooms. The Chairman has a private bathroom, while there are two single unisex bathrooms located on the west side of the 4th and 3rd floor of the main building. There are also 3 unisex bathrooms located on each floor of the C building. Each floor of the main building consists of a kitchenette, which includes refrigerator, microwave, dishwasher and ice maker. There are also coffee bars located on each B-wing and West side of the building, including each tenant having their own isolated coffee bar, microwave and refrigerator for privacy. Generator The building contains 1 (one) back-up generator. The generator was replaced in 1998 to a 100KW Natural gas generator also included was a new transfer switch panel. All batteries were replaced on the UPS system in 2010 Cafeteria Fully furnished with tables/chairs, including soft seating, 600 pound ice maker, television, refrigerator and freezer. This space is also available for private company lunches catered by outside venues. There is also an outside picnic area available with outdoor lawn furniture, including umbrellas for shade.

Energy Management System There are light sensors installed in each office, bathrooms and private areas. Also available is a Digital Control Center with a start/stop optimizer for heating and air conditioning including ease of temperature changes when needed. ADA Compliance The building is currently compliant with the Americans with Disabilities Act Auditorium 2,400 SF available for leasing and/or hosting events such as listening parties, presentations, meetings, seminars, etc. Security System The building consists of a secure card-key access program. The security system is monitored by ACS Monitoring. Historical Landmark The building is also registered as a Historical Landmark .

10 | Cassidy Turley

Made with